The Sensor, (not to be found in internal systems) has a standard value of 200 ohms. This value changes rapidly when quickly touched with a metal object. You will not be able to pinpoint the value it changes to, as this is too quick, but there must be a change.
IMPORTANT: Ignition coils, regulator and advance unit (so you have) cannot be tested for resistance value. Please refrain from doing so, you will not get any sensible information, but risk destruction.

values for old type mz-b tronics here

type of stator

Version

resistance between

Ohm


external sensor system

6 Volts black-black (lightcoil) 0,25
white-red (ignition pole) 600
12 Volts black-black (lightcoil) 0,34
white-red (ignition pole) 600


internal sensor system

6 Volts black-black (lightcoil) 0,25
red-brown (ignition pole) 500
white-brown (impuls pole) 70
12 Volts black-black (lightcoil) 0,34
red-brown (ignition pole) 500
white-brown (impuls pole) 70
back to
trouble shooting